How to call a Syspro Business Object from a SQL Trigger

Sometimes one of the worst options for customising Syspro, using a SQL Trigger, is the best option you've got. In that circumstance, how do you call a Syspro Business Object from within the SQL Trigger? Here are some ways:

Create a CLR Stored Procedure

Create a CLR Stored Procedure and call that from your SQL Trigger. In your CLR Stored Procedure, you can call the Business Object via one of Syspro's COM Objects, or via Syspro's web service or Syspro's WCF service. However, you must watch out for the 32/64-bit issue:

Watch out for the 32/64-bit issue

If you are using one of Syspro's COM objects, you may run into the problem of trying to run a 32-bit application in a 64-bit process, which can't be done (unless you want to hack around with the registry as described here - good luck). This problem arises because if your version of SQL Server is 64-bit, then you won't be able to access any 32-bit COM objects from it (such as Encore.dll or Syspro32.dll); you could use Syspro.dll (which is 64-bit), but at the time of writing, September 2014, it had't been released.

You could overcome the 32-64 bit disconnect by using Inter-Process Communication or some other communication method, but you may just find it easier to use another method.

Call a COM Object

You CAN call a COM object directly from a SQL Trigger using the extended stored procedures, sp_OACreate and sp_OAMethod (details here).
Then you could either call a web service, or call Encore.dll or Syspro.dll (being mindful of the 32/64-bit issue as mentioned above). Here's one example.
However, this is not a good solution due to the level of security you have to give to run those extended stored procedures.

Use Document Flow Manager

You could dump out files and feed them into Syspro's Document Flow Manager, a server process which monitors a directory for files and feeds them into Syspro via one of Syspro's e.Net interfaces.

Call a separate process via xp_cmdshell

The quickest and simplest method is: from your SQL Trigger, use the xp_cmdshell function, e.g.

EXEC master..xp_cmdshell @yourParameters
This has the same security issues as calling a COM Object, but it isolates your process from the SQL Server, and so this is probably the best method.

Monday, 21 April 2014

How to use XSD2Code for SYSPRO’s Business Objects

When you call one of SYSPRO’s API’s, called a Business Object, via a web service or COM or DCOM or WCF, you need to pass it some XML. That XML is defined in a couple of XSD files. Generating that XML can be done easily in C# or VB .Net using a tool such as XSD2Codewhich is available from http://xsd2code.codeplex.com/. (Note that for Visual Studio 2012, you need XSD2CODE Beta Version 3.5 or later.)
The advantage of using a C# object rather than coding your XML as one big string is you get the advantages including:
  • Intellisense in Visual Studio – it shows you descriptions about each XML element from the XSD file’s annotations
  • Type safety
  • Easier to code: you don’t have to convert your types to strings, nor worry about maximum lengths etc. – it’s all done for you.
( I also tried using Microsoft’s XSD.exe tool, but found XSD2Code to be far superior – it is more configurable and so can be made to fit SYSPRO.)
These instructions are written for XSD2Code version 3.4 with Visual Studio 2010 and SYSPRO 6.1.
  1. Download and install XSD2Code. It integrates naturally with Visual Studio.
  2. From the <SYSPRO installation directory>/BASE/SCHEMAS directory,  add the XSD files for your desired business object into your project. E.g. to call the SORTOI business object, add C:\Syspro61\Base\Schemas\SORTOI.XSD and SORTOIDOC.XSD into your Visual Studio Project. Actually, I prefer to copy the XSD files into the appropriate sub-directory of my Visual Studio project and then add them from there, so that I can put the XSD files under source code control. (I use Mercurial.)
  3. In the Visual Studio Solution Explorer, right-click on the new XSD file and select Run XSD2Code Generation.
  4. Set the following parameters; the rest can stay as their default values. This is the key bit:
    1. PropertyParams/GeneratePropertyNameSpecified must be None, otherwise you won’t get parameters generated unless you set the correspondingfieldSpecified to true.
    2. Set the Code/NameSpace to <your-namespace> + the XSD name, so that there aren’t clashes with other XSD’s that use the same internal variables. E.g. I set mine to Syspro.Base.Schema.SORTOI and Syspro.Base.Schema.SORTOIDOC.
    3. Set the Code/TargetFramework to Silverlight or Net40 as appropriate.
    4. Leave the Serialization/DefaultEncoder as UTF-8.
    5. Set Serialization / Enabled to True. This saves you having to write your own serialization routine.
    6. Set Serialization / GenerateXMLAttributes to True.
  5. Press the Generate button.

Here is a screen shot of settings to use if you are using XSD2Code version 3.5:

Group your files
In the Visual Studio Solution Explorer, to have the newly generated .cs file (e.g. SORTOI.designer.cs) grouped under the XSD file (e.g. SORTOI.XSD), i.e. as a branch UNDER the XSD file instead of as a sibling file, follow these instructions:
  1. Close Visual Studio.
  2. Edit the .csproj file for that project with a text editor (such as vim or Notepad).
  3. Add DependentUpon tags (and open and close the Compile tag).
    E.g. change this line:
    <Compile Include="Schema\SORTOI.designer.cs" />
    to this:
    <Compile Include="Schema\SORTOI.designer.cs">
    <DependentUpon>SORTOI.XSD</DependentUpon>
    </Compile>

Use Namespaces

Note that when you tell XSD2Code what namespace to use, you need to use a different namespace for each XSD file as many of SYSPRO’s XSD files use properties with the same name, and you need to avoid those names clashing.
For example, for SOIRTOI.XSD, you could use a namespace of Syspro.Base.Schema.SORTOI;
for SORTOIDOC.XSD, you could use a different namespace such as Syspro.Base.Schema.SORTOIDOC.In other words, don’t use the same namespace for all your business objects. 
Then, in your C# code, you can add a reference to your Syspro.Base.Schema project, and you might like to write using statements such as these:
using SORTOI = Syspro.Base.Schema.SORTOI;
using SORTOIDOC = Syspro.Base.Schema.SORTOIDOC;
Then you will be able to access the generated objects with minimal namespace paths in your code.

Generate your XML

Now you can create code your XML settings using plain old C# objects as simply as this example:
var SORTOI_Parameters = new SORTOI.PostOrders()
{
 Parameters = new SORTOI.Parameters()
 {
     ValidateOnly = PORTOI.ValidateOnly.Y,
     StatusInProcess = PORTOI.StatusInProcess.N
 }
};

Edit the code to correct List definitions

Some List definitions in SYSPRO’s XSD files don’t seem to be properly declared, so you may have to manually edit the generated code and find all lines that begin with public List and add a line like this above the declaration (change the parameter on the right to match your type):
[System.XML.Serialization.XmlElementAttribute("Item")]
so that the final code looks like this example:
[System.Xml.Serialization.XmlElementAttribute("Item")]
public List<SetupQotNonStockItem> Item
This problem only occurs for certain XSD files (such as WIPTPBDOC.xsd), where-as others such as PORTOIDOC.xsd have perfectly-generated code. My guess is that some of SYSPRO’s XSD files are not well constructed.
(Note that XSD2Code’s GenerateXMLAttributes option creates these XmlElementAttributes automatically… if the XSD code is correct.)

Sometimes the XSD file is incorrect

Sometimes the XSD file is actually incorrect. I am getting such problems reported and corrected if and when I find them. See this forum post for more information.

If you right-click on the XSD file but can’t see “Run XSD2Code generation”

If you right-click on your XSD file but can’t see Run XSD2Code generation enabled, this may be because the highlighted file has just switched to a different file, due to some behaviour in Visual Studio. To work around this, double-click on your XSD file first so that it comes up for editing; then you will be able to right-click on the XSD file and generate code for it.

Serialize your objects

To convert your object to XML, you can use code such as this:
string XmlParameters = SORTOI_Parameters.Serialize();

Syspro’s VBScript Business Objects don’t like namespace declarations

Note that if you may have XML Namespace declarations in your XML from serialization like this:
<Orders xmlns:xsi=""http://www.w3.org/2001/XMLSchema-instance"" xmlns:xsd=""http://www.w3.org/2001/XMLSchema""">
This shouldn’t be a problem BUT if you are passing this XML to Syspro’s VBScript and then calling a Business Object from VBScript, it will not like the xmlns declaration, so you may want to add this code on the VBSCript side (see related article, How to invoke a Syspro VBScript function from a .Net User Control):
Dim nameSpaceDeclaration
nameSpaceDeclaration = "xmlns:xsi=""http://www.w3.org/2001/XMLSchema-instance"" xmlns:xsd=""http://www.w3.org/2001/XMLSchema"""
XmlParameters = Replace(XmlParameters, nameSpaceDeclaration,"")
This was the case for Syspro 6.1 Port 69.
However, this doesn’t seem to be an issue if calling the Business Object not from VB Script but from a web service or via DCOM.

Adjust the encoding for Silverlight

If you are using this in Silverlight, you may need to adjust the XML encoding; this is an ugly way of doing it:
XmlParameters = XmlParameters.Replace("encoding=\"utf-8\"", "encoding=\"Windows-1252\"");
A better way of doing this may be to pass the Serialize routine a parameter to select which encoding to use; I have yet to try this.

Finally

Then you can pass those XML strings to the web service for the business object, e.g:
setupProxySORTOI.AddAsync(userId, "SORTOI", XMLParameters, XMLIn);

See Also

Friday, 22 March 2013

How to fix {FE41B1AD-0F2B-459C-9668-5FC6BBF093EE} Class not registered in Syspro

There are a number of reasons why you can get this error in Syspro:


Error
System.Web.Services.Protocols.SoapException: Server was unable to process request. ---> System.Runtime.InteropServices.COMException: Retrieving the COM class factory for component with CLSID {FE41B1AD-0F2B-459C-9668-5FC6BBF093EE} failed due to the following error: 80040154 Class not registered (Exception from HRESULT: 0x80040154 (REGDB_E_CLASSNOTREG)).
   at SysproServices.utilitiesclass.Logon(String Operator, String OperatorPassword, String CompanyId, String CompanyPassword, Language LanguageCode, LogDetail LogLevel, Instance EncoreInstance, String XmlIn)
   --- End of inner exception stack trace ---


Encore.dll not registered

The CLSID, {FE41B1AD-0F2B-459C-9668-5FC6BBF093EE}, refers to Encore.DLL, which is a 32-bit DLL that should live under your Syspro base folder, e.g. C:\Syspro61\Base\Encore.dll.

This DLL should be registered; you can register this by running an elevated command prompt and running these commands:

cd C:\Syspro61\Base
regsvr32 Encore.dll

Run as a 32-bit process

However, the problem usually happens when you run a 64-bit process and try to access Encore.dll, which is a 32-bit dll, because you can't mix 32-bit code with 64-bit code in the one process.

Therefore, to talk to Syspro's E.Net BUsiness Objects, you may have to change your process so that it is a 32-bit process.

If you made your own program using Visual Studio to access Syspro via E.Net, then you can force your application to run as a 32-bit process using this procedure:

In Visual Studio, go to Tools / Options / Projects and Solutions / General and tick Show advanced build configurations as shown in the screen shot below.


Then go to Build / Configuration Manager, click on the options for Platform, go to New, add x86, and set the Platform to x86, as shown in the screen shot below. You should do this process for both the Debug and the Release configurations.


Then rebuild your application.

Run as a 64-bit process - use web services

Another solution is to change from talking to Syspro's Business Objects via Encore.dll, to using Syspro's Web Services instead. If you are using VBScript / VBA in Excel or a similar Microsoft Office application, see this post for how to change to using web services.

Configure IIS correctly

Another source of the problem can be because of incorrect configuration of IIS for Syspro's E.Net web services. This can typically happen if you install Syspro Web Services BEFORE configuring IIS for Syspro Web Services. If that is the case, see this post this post for more detail on setting up IIS correctly for Syspro.